OS Power Group

Reliable power in any conditions

NFPP and LFP energy storage, generation and modular data centers for sites at -40 °C and +55 °C. One product range for every scenario - from a base station to an oil and gas field and a data center.

NFPP and LFP energy storage, generation and solar plants for sites in heat up to +55 °C. Uninterrupted power for industrial sites, data centers and base stations.

Operation at -40 °C
NFPP energy storage for northern sites and equipment for hot climates up to +55 °CCompare in frost and heat
Running until the grid is restored
Storage picks up the load instantly, a diesel generator keeps the site running for the whole outage
Complete solutions for your scenarios
Base stations, oil and gas fields, data centers and industrial plants: storage, generation and power supply in one project
Lower capacity charges
Peak shaving and load shifting reduce billed capacity; the effect depends on the load profile and tariff category of the site
Operation at +55 °C
Climate-controlled cabinets and containers protect equipment from dust and overheatingCompare in frost and heat
Running until the grid is restored
Storage picks up the load instantly, a diesel generator keeps the site running for the whole outage
Solar + storage
Daytime solar output is shifted to the evening peak and the night
Less diesel consumption
Storage takes over peaks and low loads, the generator runs in its economical mode

How we differ from the alternatives

Why OS Power

Chinese manufacturing behind us, a local company at your side: world-class equipment, compliance with market requirements and full life-cycle support on site.

Not an importer, but an accountable supplier

Authorized representative of the manufacturer, EAEU conformity assessment by the group's Russian company, spare parts, commissioning and on-site service.

Hours, not minutes

1-4 hours of autonomy from energy storage instead of minutes from a UPS; with a variable load profile, the declared grid connection capacity drops by 20-50%.

The whole chain under one contract

From the 6-35 kV incoming feeder to the rack: energy storage, power distribution, generation and modular data centers with one warranty and one point of responsibility.

Sodium where lithium gets cold

48 V sodium-ion modules discharge at -40 °C and charge from -20 °C without heating; 115 kWh cabinets operate from -25 to +55 °C (per manufacturer specification).

Safety in measurable figures

Peak thermal runaway temperature of an NFPP cell is 286 °C versus 361 °C for LFP, and the temperature rises more slowly. Fire suppression and a battery management system in every cabinet and container.

Cycle life and efficiency with conditions

LFP cabinets of 107.5 and 215 kWh: at least 8,000 cycles; the 261 kWh cabinet on 314 Ah cells: at least 6,000 cycles at 0.5P and 100% DOD. NFPP cell efficiency up to 97% DC; AC-AC round-trip efficiency of LFP cabinets 89-90%.

NFPP sodium-ion

Sodium-ion for northern climates

48 V sodium-ion modules discharge at -40 °C and charge from -20 °C without heating; 115 kWh cabinets operate from -25 to +55 °C (per manufacturer specification). Thermal runaway in an NFPP cell develops more slowly and at a lower peak temperature than in LFP. The cell manufacturer, a partner of the group, is one of the largest sodium-ion battery manufacturers by 2025 shipments (manufacturer data).

-40 °Clower discharge limit of 48 V sodium-ion modules
15,000+cell cycles in factory tests; 8,000+ per the 48 V module datasheet
0 Vsafe transportation
286 °Cpeak thermal runaway temperature of an NFPP cell versus 361 °C for LFP

Certification

Documentation for tenders and market approval

Products of the group's manufacturers are certified to international and Chinese standards. EAEU conformity assessment is carried out by the group's Russian company as the applicant for each item; the list of valid documents is available on request.

  • ISO 9001
  • ISO 14001
  • CE
  • UN38.3
  • IEC 62619 (lithium systems)
  • GB/T 44265-2024 (sodium-ion systems)

Applicable EAEU requirements: 0.4 kV equipment - TR CU 004 and TR CU 020; 48 V modules - TR CU 020 and TR EAEU 037; 6-35 kV switchgear - voluntary certification and approval by the grid company for each project.

Geography

Manufacturing in China, projects in seven markets

China Russia, Moscow Belarus, Minsk Kazakhstan, Astana Uzbekistan, Tashkent Europe, Düsseldorf Middle East
Manufacturing Markets and offices
  • China - Headquarters and manufacturing: Taicang, Hong Kong, partner plants
  • Russia, Moscow - Sales and technical support
  • Belarus, Minsk - Projects with partners
  • Kazakhstan, Astana - Regional centre (opening)
  • Uzbekistan, Tashkent - Projects with partners
  • Europe, Düsseldorf - Group partner in Europe
  • Middle East - Telecom operators in Egypt and Turkey

Inquiry

Which product are you interested in?

Describe your site and objective. An OS Power engineer will select a solution and prepare a proposal.

Add details: name, country, file

Prefer a messenger? Write to an engineer on Telegram or WhatsApp - we reply during business hours.

Request