Genset + storage hybrid calculator

Enter load, operating hours and fuel prices to compare genset only with genset + storage by fuel, engine hours, service and CO2. The calculation runs in your browser.

The calculation is preliminary and is not a commercial proposal. Assumptions are listed below the result.

Region
Your prices

Annual result

Genset onlyGenset + storageSavings
fuel and service savings over 10 years

Preliminary. For your site we calculate using the hourly load profile and actual prices.

How we calculate
Genset consumption
Consumption model: 0.08 l/h per kW of rating plus 0.25 l per kWh generated. Rating is the installed genset; the hybrid uses the same genset.
Hybrid
The genset runs only to charge and carry the load at 80 % of rating, then stops. Storage AC-AC round-trip efficiency is 89 %. Storage is sized for 4 hours of average load at 90 % depth of discharge.
Solar
Daily yield per 1 kW of panels, annual average: north 2.5 kWh, central 3.2 kWh, south 4.5 kWh.
CO2
2.68 kg per liter of diesel fuel.
Not included
Cost of storage and its installation, genset overhaul, discounting. Payback is calculated in the commercial proposal.