Illustration: an autonomous OS Power data center site with energy storage, gensets and a solar plant

Backup site

A backup site that does not depend on the local grid

A single site is a single point of failure. A modular data center with its own power infrastructure is commissioned in months and carries the load for hours without the grid. We work in Russia and in EAEU countries where hosting is lawful for your type of data.

4-6 months

for a 1 MW site with power in place at the host

OS Power calculation

3-4 hours

of autonomy from OS Power battery storage

OS Power calculation

48-72 hours

of genset operation on stored fuel

OS Power calculation

Why

Why distributed redundancy

Single point of failure

A geographically remote backup reduces the risk of business interruption in case of an accident, outage or loss of access to the primary data center.

Months, not years

A modular site is commissioned in 4-6 months with a ready grid connection at the host; conventional construction takes 18-30 months.

Hours of autonomy instead of minutes

OS Power battery storage for 3-4 hours and gensets with fuel reserves: the site does not depend on the stability of the local grid.

Configurations

Three typical options

OptionIT capacityFormatPower
A100 kWfactory-built IT module with cooling and power distribution3-4 h battery storage, genset
B500 kWseveral IT modules or a micro-module, cooling plant3-4 h battery storage, N+1 gensets
C1,200 kWprefabricated building of modules, cooling plant, 6-35 kV power module3-4 h battery storage, N+1 or 2N gensets

Lawful

What can be hosted abroad

Russian law prohibits the primary collection of personal data of Russian citizens abroad; critical information infrastructure facilities and production banking systems are not moved abroad. Lawful scenarios:

Backups and archives
Copies of data and systems, long-term storage.
Disaster recovery
A site to which systems fail over if the primary data center fails.
Model training
Computing and model training on anonymized data.
Business in the host country
Infrastructure for your company operating in Kazakhstan, Uzbekistan or Belarus.

Latency

Latency to Moscow

Minsk
13-20 ms (estimate)
Tashkent
about 55 ms
Almaty
about 60 ms

With latency above 50 ms synchronous replication is ruled out; asynchronous replication works.

Model

Host and OS Power

The host partner provides

  • Land and the site
  • Power supply and grid connection
  • Licenses and resident status
  • Connectivity and security
  • Capacity lease agreement with the customer

OS Power supplies

  • Factory-built data center module
  • Battery storage for 3-4 hours of autonomy
  • Generation and fuel reserve
  • Power equipment and power distribution
  • Installation, commissioning and service

A legal assessment of hosting is carried out for the type of workload and data before the contract is signed. Latency values are measurements and estimates as of 10.2026.

Request

Tell us about your site

IT capacity and rack type, redundancy and autonomy requirements, location and climate, availability of a grid connection, target launch date. Within a week we will prepare a concept, an equipment list and a schedule.

Add details: name, country, file

Prefer a messenger? Write to an engineer on Telegram or WhatsApp - we reply during business hours.

Request